Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Braz. dent. j ; 34(5): 63-71, Sept.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528017

ABSTRACT

Abstract This study evaluated the effect of toothbrushing on enamel-cementing material-ceramic bonded interfaces, using different cementing materials. Materials and Methods: Thirty enamel and thirty ceramic blocks were bonded with cementing materials to produce the samples that were bonded with three types of cementing materials: 1- RelyX Ultimate resin cement (REXU), 2- RelyX Unicem 2 self-adhesive resin cement (REU2) and 3- heated Z100 restorative composite (60°C). Bonded interfaces of the samples were toothbrushed and the surfaces of the 3 cementing materials were evaluated for roughness (RG, in µm), roughness profile (RP, in µm), and volume loss (VL, in µm3) (baseline and after 20,000 and 60,000 toothbrushing cycles). Data were evaluated by Generalized Linear Analysis (two factors: "material" and "toothbrushing cycle") and Bonferroni test (α=0.05). Results: REXU and Z100 exhibited lower RG than that presented by REU2, except after 60,000 toothbrushing cycles when only Z100 differed from REU2. The increase in toothbrushing cycles increased the RG and RP for all materials. REU2 also showed higher RP than those showed by REXU and Z100 when it was analyzed regarding the enamel. The VL of Z100 was the lowest with 20,000 toothbrushing cycles, regarding the enamel and ceramic. For 60,000 cycles, REXU showed the lowest VL regarding the ceramic, and REU2 had the highest VL regarding the enamel and ceramic. Conclusion: In general, REXU and Z100 showed the best results regarding the evaluations performed and the REU2 exhibited the highest RG, RP, and VL.


Resumo Este estudo avaliou o efeito da escovação nas interfaces de união esmalte-material cimentante-cerâmica, utilizando diferentes materiais cimentantes. Materiais e Métodos: Trinta esmaltes e trinta blocos cerâmicos foram unidos com materiais de cimentação para produzir as amostras que foram unidas com três tipos de materiais de cimentação: 1- cimento resinoso RelyX Ultimate (REXU), 2- cimento resinoso autoadesivo RelyX Unicem 2 (REU2) e 3-compósito restaurador aquecido Z100 (60°C). As interfaces coladas das amostras foram escovadas e as superfícies dos 3 materiais cimentantes foram avaliadas quanto à rugosidade (RG, em µm), perfil de rugosidade (RP, em µm) e perda de volume (VL, em µm3) (baseline e após 20.000 e 60.000 ciclos de escovação). Os dados foram avaliados por Análise Linear Generalizada (dois fatores: "material" e "ciclo de escovação") e teste de Bonferroni (α=0,05). Resultados: REXU e Z100 apresentaram menor RG do que REU2, exceto após 60.000 ciclos de escovação, quando Z100 diferiu apenas de REU2. O aumento dos ciclos de escovação aumentou o RG e RP para todos os materiais. O REU2 também apresentou PR maior que o REXU e Z100, quando analisado em relação ao esmalte. O VL de Z100 foi o menor com 20.000 ciclos de escovação em relação ao esmalte e cerâmica. Para 60.000 ciclos, o REXU apresentou o menor VL em relação à cerâmica e o REU2 o maior VL em relação ao esmalte e à cerâmica. Conclusão: De maneira geral, REXU e Z100 apresentaram os melhores resultados nas avaliações realizadas e o REU2 apresentou os maiores RG, RP e VL..

2.
Braz. oral res. (Online) ; 36: e093, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384196

ABSTRACT

Abstract: The aim of the study was to evaluate how the association of solvents (tetrahydrofuran [THF], dimethyl sulfoxide [DMSO], ethanol [ET] or acetone [ACT]) with experimental dental adhesives affects selected properties of experimental dental adhesives and dentin bond durability. Six adhesive combinations were prepared containing: 30 % ET, 30 % ACT, 30 % THF, 28 % ET + 2 % DMSO (ET+DMSO), 15 % ethanol + 15 % THF (ET+THF), or 28 % THF + 2 % DMSO (THF+DMSO). Thirty-six molars (n = 6) were cut to expose the coronary dentin, and were randomly divided according to the adhesives. They were restored, and then cut into resindentin sticks (1 mm²), and stored in distilled water for 24 h or 6 months, until conducting the microtensile bond strength and nanoleakage tests. Other experiments performed with adhesives included viscosity assessment using a rheometer, and degree of conversion using Fourier-transform infrared spectroscopy (FTIR). The data were analyzed statistically using two-way ANOVA and Tukey's test (p < 0.05). The adhesive formulated exclusively with THF showed the highest viscosity, followed by ET+THF, which obtained the highest degree of conversion compared to ET, and THF alone. ET+DMSO obtained the highest 24-h and aged bond strengths (p < 0.05). ET+THF increased the nanoleakage slightly after 6 months, but attained the only gap-free adhesive interface among all the groups. The combination of alternative solvents, particularly THF, with conventional ones (ET) has improved chemical properties, and the dentin bonding of experimental simplified adhesives.

3.
Braz. dent. sci ; 24(4, suppl 1): 1-9, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1352595

ABSTRACT

Objective: The aim of this study was to evaluate the microshear bond strength of Universal adhesives to enamel and dentin after one week and eighteen months of water storage. Material and Methods: Fragments from the buccal surfaces of 80 bovine teeth were prepared (12x5x1.0 mm) and ground to obtain flat surfaces of enamel and dentin. Samples were randomly assigned to 8 experimental groups (n=10), according to four adhesive systems (Adper Single Bond Plus/control ­ not a Universal adhesive/ASB; Ambar Universal/AUN; Prime&Bond Active/PBA and Scotchbond Universal/SBU) and two water-storage times (one week and eighteen months after sample preparations). Adhesives were applied according to the manufacturers' instructions and molds were positioned over bonded surfaces. A flowable composite was poured into the molds to fill up their internal diameter and obtain resin cylinder (1.0mm height/0.7mm internal diameter) after light-curing. Bond strength was determined using a testing machine (0.5 mm/min) and data were statistically analyzed by two-way analysis of variance (ANOVA) and the post-hoc Tukey's test (alpha=0.05). Failure patterns were analyzed for all resin cylinder tested. Results: For enamel, differences among adhesives were observed only at 18 months, in which SBU produced lower bond strength values (15.9±3.0 MPa) than the others universal adhesives (AUN: 19.3±4.8 and PBA: 21.4±2.1 MPa) (p<0.05). For dentin, there were differences among adhesives only at 7 days, with PBA showing the highest bond strength (37.4±4.9 MPa) and ASB the lowest one (19.4±3.9 MPa) (p<0.05). Enamel and dentin bond strength of all adhesives decreased significantly after 18 months and reduction percentage varied from 36.9 to 52.4 for enamel and from 35.1 to 62.8 for dentin. Adhesive and mixed failures showed high incidences. Conclusion: Results suggested that adhesives presented differences among them depending on type of hard dental tissue and evaluation time. Enamel and dentin bond strengths of control and all universal adhesives tested were not stable, decreasing at eighteen months. (AU)


Objetivo: O objetivo deste estudo foi avaliar a resistência de união ao microcisalhamento de adesivos universais ao esmalte e dentina após uma semana e dezoito meses de armazenamento em água. Material e Métodos: Fragmentos da superfície vestibular de 80 dentes bovinos foram preparados (12x5x1,0 mm) até o obtenção de superfícies planas de esmalte e dentina. As amostras foram distribuídas aleatoriamente em 8 grupos experimentais (n=10), de acordo com quatro sistemas adesivos (Adper Single Bond Plus / controle - não universal; Ambar Universal; Prime & Bond Active e Scotchbond Universal) e dois tempos de armazenamento em água (uma semana e dezoito meses após o preparo das amostras). Os adesivos foram aplicados de acordo com as instruções dos fabricantes e as matrizes foram posicionadas sobre as superfícies aderidas. Um compósito fluido foi aplicado nas matrizes para preencher seu diâmetro interno e obter o cilindro do compósito por fotopolimeração (1,0 mm de altura / 0,7 mm de diâmetro interno). A resistência de união foi determinada em uma máquina universal de ensaios (0,5mm/min). Os dados foram analisados estatisticamente pela análise de variância dois fatores (ANOVA) e teste de Tukey (alfa 0,05). Resultados: Para o esmalte, foram obtidas diferenças apenas aos 18 meses, em que Scotchbond Universal produziu menor média de resistência de união do que os demais adesivos universais. Para dentina, houve diferenças entre os adesivos apenas aos 7 dias, com o Prime & Bond Active apresentando a maior resistência de união e o Adper Single Bond Plus a menor. Os resultados sugeriram que os adesivos apresentaram diferenças entre si dependendo do substrato e do tempo de avaliação. Conclusão: As resistências de união em esmalte e dentina do controle e de todos os adesivos universais testados não foram estáveis, diminuindo aos dezoito meses (AU)


Subject(s)
Water Storage , Dentin-Bonding Agents , Dental Enamel , Dentin
SELECTION OF CITATIONS
SEARCH DETAIL